LF Overview

ME-Series

  Easy Evaluation Professional Analysis
ME-AnalyserME3030ME3830ME3840ME3851ME3951
Frequency Ranges
16 Hz - 2 kHz x        
16 Hz - 100 kHz   x      
5 Hz - 100 kHz     x x  
5 Hz - 400 kHz         x
Filter module 16.7 Hz / 50 Hz / 2 kHz     x x x
Measuring Range
0.1 - 2,000 nT/Vm x x x x x
0.1 - 2,000 nT/Vm       x x
Sensors
Internal 1D magnetic field sensor          
Internal sensors bound to earth potential in Y-direction x x x x x
Internal potential-free 1D-E-field sensor in Y-direction (increased tolerance) x x x x x
TCO-compliant E-field sensor "TCO Light" (mountable)       opt. opt.
Features
AC and DC outputs       x x
Auto power-off x x x x x
Scope of Supply and Optional Accessories
9 V battery x x x    
NiMH rechargeable battery       x x
Power supply unit       x x
Certificate of calibration with frequency run " KAL-NF"       opt. opt.
Grounding cable x x x x x
Grounding clamp       x x
Potential-free telescopic rod opt. opt. opt. opt. opt.
Plastic transport case opt. opt. opt. x x

NFA-Series

  Professional Analysis
3D NF-AnalyserNFA30MNFA400NFA1000
Frequency Ranges
16 Hz - 32 kHz x    
5 Hz - 400 kHz   x  
5 Hz - 1 MHz     x
Frequency selective filter 16.6 | 50/60 | 100/120 | 150/180 | rest < 2 kHz | > 2kHz x x x
Magnetic Flux Density
Measuring range "M" in Nanotesla (alternatively displayed in Milligauss) 1 - 19,999 nT 
Internal 3D sensor (isotropic point < 3cm³) x x x
Electric Field Strength
Measurement range in Volt per meter (V/m) 1)   0.1 bis 1,999 V/m
Internal potential-free 3D-E-field sensor 2)     x
Internal potential-free 1D-E-field sensor in Y-direction   x  
Internal sensor bound to earth potential in Y-direction (TCO-Recommendation)   x x
nput for the measurement of capacitive body coupling acc. to SBM (Hand electrode opt.)   1 - 19,990 mV
Optional Sensors ("CH 4")
TCO compliant E-field sensor (diameter 30 cm, mountable) / Magnetostatic sensor / Electrostatic sensor   opt. opt.
Input for AC or DC signals (for the connection of a HF-Analyser) x x x
Signal Analysis
True RMS x x x
True RMS hold / Peak hold x x x
Peak value, broad band x x x
Display Features
Large LC display (4 digits), also easy to read from afar x x x
Frequency indication by differently coloured LEDs or by numerical value   x x
Acoustic signal (Geiger-counter-effect, volume adjustable)   x x
Internal Data Logger
Sampling rate: 110,000 samples/sec 3) x x x
Voice-recorder   x x
Configuration and evaluation software for PC x x x
Scope of Supply and Optional Accessories
Internal Li-Ion battery pack 4) x x x
Terminal nut for the stand integrated at the bottom of the housing   x x
Floating potential telescopic rod   opt. opt.
Kompakter Kunststoffkoffer K5 x x x
Certificate of calibration opt. opt. opt.

1) Optional range extension upon request
2) Patent DE 10 2007 025 911
3) maxima are saved up to 10 times/sec onto the SDHC card. Simultaneous and frequency selective for XYZ and CH4, i.e. without "blind spots"
4) for up to 36 h "full speed"-recordings, NFA 30M more than 48h

opt. = optional

ME-Series   Easy Evaluation Professional Analysis ME-Analyser ME3030 ME3830 ME3840 ME3851 ME3951 Frequency Ranges 16 Hz - 2 kHz x    ... read more »
Close window
LF Overview

ME-Series

  Easy Evaluation Professional Analysis
ME-AnalyserME3030ME3830ME3840ME3851ME3951
Frequency Ranges
16 Hz - 2 kHz x        
16 Hz - 100 kHz   x      
5 Hz - 100 kHz     x x  
5 Hz - 400 kHz         x
Filter module 16.7 Hz / 50 Hz / 2 kHz     x x x
Measuring Range
0.1 - 2,000 nT/Vm x x x x x
0.1 - 2,000 nT/Vm       x x
Sensors
Internal 1D magnetic field sensor          
Internal sensors bound to earth potential in Y-direction x x x x x
Internal potential-free 1D-E-field sensor in Y-direction (increased tolerance) x x x x x
TCO-compliant E-field sensor "TCO Light" (mountable)       opt. opt.
Features
AC and DC outputs       x x
Auto power-off x x x x x
Scope of Supply and Optional Accessories
9 V battery x x x    
NiMH rechargeable battery       x x
Power supply unit       x x
Certificate of calibration with frequency run " KAL-NF"       opt. opt.
Grounding cable x x x x x
Grounding clamp       x x
Potential-free telescopic rod opt. opt. opt. opt. opt.
Plastic transport case opt. opt. opt. x x

NFA-Series

  Professional Analysis
3D NF-AnalyserNFA30MNFA400NFA1000
Frequency Ranges
16 Hz - 32 kHz x    
5 Hz - 400 kHz   x  
5 Hz - 1 MHz     x
Frequency selective filter 16.6 | 50/60 | 100/120 | 150/180 | rest < 2 kHz | > 2kHz x x x
Magnetic Flux Density
Measuring range "M" in Nanotesla (alternatively displayed in Milligauss) 1 - 19,999 nT 
Internal 3D sensor (isotropic point < 3cm³) x x x
Electric Field Strength
Measurement range in Volt per meter (V/m) 1)   0.1 bis 1,999 V/m
Internal potential-free 3D-E-field sensor 2)     x
Internal potential-free 1D-E-field sensor in Y-direction   x  
Internal sensor bound to earth potential in Y-direction (TCO-Recommendation)   x x
nput for the measurement of capacitive body coupling acc. to SBM (Hand electrode opt.)   1 - 19,990 mV
Optional Sensors ("CH 4")
TCO compliant E-field sensor (diameter 30 cm, mountable) / Magnetostatic sensor / Electrostatic sensor   opt. opt.
Input for AC or DC signals (for the connection of a HF-Analyser) x x x
Signal Analysis
True RMS x x x
True RMS hold / Peak hold x x x
Peak value, broad band x x x
Display Features
Large LC display (4 digits), also easy to read from afar x x x
Frequency indication by differently coloured LEDs or by numerical value   x x
Acoustic signal (Geiger-counter-effect, volume adjustable)   x x
Internal Data Logger
Sampling rate: 110,000 samples/sec 3) x x x
Voice-recorder   x x
Configuration and evaluation software for PC x x x
Scope of Supply and Optional Accessories
Internal Li-Ion battery pack 4) x x x
Terminal nut for the stand integrated at the bottom of the housing   x x
Floating potential telescopic rod   opt. opt.
Kompakter Kunststoffkoffer K5 x x x
Certificate of calibration opt. opt. opt.

1) Optional range extension upon request
2) Patent DE 10 2007 025 911
3) maxima are saved up to 10 times/sec onto the SDHC card. Simultaneous and frequency selective for XYZ and CH4, i.e. without "blind spots"
4) for up to 36 h "full speed"-recordings, NFA 30M more than 48h

opt. = optional